Category
Filters and Filter Systems Integrity Tester
FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify
Basic Info.
Model NO. | FIT-3.0/FIT-4.0 |
Trademark | Xiangyi |
Origin | China |
Production Capacity | 100 PCS/Month |
Product Description
FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify the sterilizing filter in the FDA, the State Pharmacopoeia and GMP specification requirements. The FIT-4.0 Integrity Tester is compact, handy to use, and fully automated integrity test instrument, which performs bubble point, diffusion flow, enhanced bubble point, and water-based test for hydrophobic filters. The first domestic launch of integrity test for water-based test for hydrophobic filters to meet different customer needs.Main features:
- The scientific electronic signature and classification to distinguish the responsibility easily, and to prevent false operation.
- Display of test data and curves in real time, monitoring the whole process of testing.
- Provides automatic printing set function, the user can operate more simple and convenient.
- Water Based test (WH) for Hydrophobic Filter: using purified water as test liquid instead of IPA and Ethanol, thus it can avoid trace quantity of ethanol or IPA contamination when testing filters.
- The instrument can store 500 history record and curve.
- Advanced "water intrusion method" has solved the disadvantage that the hydrophobic filter can only be tested immersed in organic solvent .
- Advanced automatic control system, no need of manual adjusting pressure, to ensure the accuracy and precision.
- Real-time displaying test data and curve, monitoring the whole testing process.
- Dual-core operation, with PC software.
- Covers all of the functions of foreign similar instruments.
- More perfect user extension management, users can change the password according to need.
- Add the automatic protection function for tested filters, to avoid doing harm to the filter because of overvoltage testing.
- Provide automatic printing setting, and make the operation more easy and convenient.
- 5.7 " backlight digital LCD, display clearly.
- Testing the Diffusion flux of the disc membrane is of important significance for judging the characteristics of the membrane.
Specifications:
Model | FIT-4.0 | FIT-3.0 |
power | 170-240VAC,50/60Hz, 110W | 170-240VAC,50/60Hz, 110W |
Maximum working pressure | 8000mbar | 8000mbar |
Minimum working pressure | 100mbar | 100mbar |
Dimensions (L*D*H)mm | 240X380X285 | 400X380X235 |
Test pressure | 500-6900 mbar | 500-6900 mbar |
Test accuracy | Upstream volume test: ± 4%; bubble point: ± 50 mbar; diffusion flow: ± 4%; water immersion: ± 0.1 ml/min | Upstream volume test: ± 4%; bubble point: ± 50 mbar; diffusion flow: ± 4%; |
Working condition | Temperature: 5ºC±35ºC;Moisture: 10~80% | Temperature: 5ºC±35ºC;Moisture: 10~80% |
Test time | Upstream volume test : 5min±2min;Quick D test: 10min±2minBase BP test: 15min±2minEnhanced test: 20min±2minwater immersion: +5min±2min | Upstream volume test : 5min±2min;Quick D test: 10min±2minBase BP test: 15min±2minEnhanced test: 20min±2min |
Checklist print | Input parameters & output data and result | Input parameters & output data and result |
History record | 500 test records + graphic curves | 500 test records + graphic curves |
LCD | 5.7″ ; TFT, monocular | 5.7″ ; TFT, monocular |
Series I/O type | RS232 | RS232 |
Language of menu | English | English |