Gc Laboratory Gas Chromatography Instrument Portable Dissolved Gas Analysis for Transformer Oil
Basic Info.
Model NO. | GC-7890-DL |
Mini Detect Concentration of Hydrogen | ≤2ppm |
Detector 1 | Thermal Conductivity Detector (Tcd) |
Detector 2 | Flame Ionization Detector (Fid) |
Structure | Transformer Oil Dissolved Gas Analyzer |
Test Sample | Transformer Oil |
Tcd Sensitivity | S≥8000mv.Ml/Mg |
Fid Detection Limit | Mt≤1*10-12g/S |
Product Name | Transformer Oil Dissolved Gas Analyzer |
Gas Items | H2, O2, N2, Co, CO2, CH4, C2h4, C2h6, C2h2 |
Transport Package | Plywood Case |
Trademark | GOLD |
Origin | Chongqing, China (Mainland) |
HS Code | 9030849000 |
Production Capacity | 500 Pieces/Month |
Product Description
AGC Laboratory Gas Chromatography Instrument Portable Dissolved Gas Analysis For Transformer Oil About the analysis of dissolved gases in transformer oil: hydrogen (H2), oxygen (O2), nitrogen (N2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), ethylene (C2H4), ethane (C2H6), acetylene (C2H2).Introduction
1) GC Laboratory Gas Chromatography Instrument Portable Dissolved Gas Analysis For Transformer Oil is an effective means to achieve gas chromatography. Gas chromatography with a high-performance high selectivity, high sensitivity, rapid analysis, small sample volume, wide range of applications and so on. Chromatography can be widely used systems and scientific research institutes and universities in areas such as health and epidemic prevention, environmental monitoring, quality supervision, petrochemical, pharmaceutical, commodity inspection, public security, food, electricity, liquor, mines and so on.
2) GC Laboratory Gas Chromatography Instrument Portable Dissolved Gas Analysis For Transformer Oil is controlled by a microcomputer, a higher cost performance of the gas chromatograph, can be equipped with a thermal conductivity detector (TCD), flame ionization detector (FID). Can be installed packed column and capillary column oven can be heated and temperature-programmed operations.
Main Technical Indicators
- FID Detection limit: Mt≤1×10-12g/s
TCD Sensitivity: S≥8000mV.ml/mg
Minimum detectable concentration of hydrocarbons≤0.1PPM
Minimum detectable concentration of hydrogen≤2PPM
Minimum detectable concentration of CO≤1PPM
Minimum detectable concentration of CO2≤5PPM - New electronic digital circuit, imported precision voltage regulator, imported precision steady flow valve, double column parallel, secondary shunt, one injection full analysis, double packed column inlet, double FID detector, quartz nozzle, TCD detector, Imported antimony tungsten wire, methane reformer, gas shutoff protection, spare parts and kits, etc.
Oven |
Temperature range: room temperature + 5 ºC ~ 400 ºC (in 1 ° C increments any set) Temperature accuracy: less than ± 0.1 ºC Cheng Ascending Order: 7 order Heating rate: 0.1 ~ 40 ºC / min arbitrarily set (0.1 ° C increments) Time Setting: 9999.9min |
Vaporization Chamber |
Temperature range: room temperature plus 6 ºC ~ 400 ºC Temperature accuracy: less than ± 0.2 ºC |
Detector |
Thermal conductivity detector (TCD) Temperature range: room temperature plus 6 ºC ~ 400 ºC Temperature accuracy: less than ± 0.1 ºC Flame ionization detector (FID) Temperature range: room temperature plus 6 ºC ~ 400 ºC Temperature accuracy: less than ± 0.2 ºC |
Detector Specifications | |
Hydrogen flame ionization detector (FID) Sensitivity: Mt≤1 × 10-12g / s The linear range: ≥107 Noise: ≤20uv Drift: ≤150uv / h | Thermal Conductivity Detector (TCD) Sensitivity: S≥8000mv • ml / mg (benzene, H2) Noise: ≤30uv Drift: ≤150uv / h |
Remark: In order to make the instrument to get the best performance, we recommend the following purity and supply pressure:
|