High Quality Lab Analysis Instruments Gas Chromatography Instrument

High Quality Lab Analysis Instruments Gas Chromatography Instrument

High Quality Lab Analysis Instruments Gas Chromatography InstrumentCHL-GC112A Main Features:1.Synchronous bidirectional
Basic Info.
Model NO. CHL-GC112A
Temperature Accuracy 0.1 Degree
Max Heating Rate 0.1-60 Degree/Min
Temperature Programming 9 Step
Temperature Range Room Temperature up 5 -400 Degree
Capacity 22L
Transport Package Carton Package
Specification 1020x 660x740 (mm) G. W. 82kg
Trademark ICLEAR
Origin China
Production Capacity 1000 Sets/Month
Product Description

High Quality Lab Analysis Instruments Gas Chromatography InstrumentCHL-GC112A

Main Features:1.Synchronous bidirectional control with touch screen on the CHL-GC112A.2.The 7-inch color touch screen on the CHL-GC112A can display the flow rate and pressure value of theelectronic gas path.3.The multi core, 32-bit embedded hardware system ensures the reliable operation of the instrument.4.One key start up function.5.The extendable synchronous external trigger function can initiate GC112A and workstation throughexternal signals, such as automatic sampling device, thermal analyzer and so on.6.The instrument has sound system self-checking function and malfunction automatic identificationfunction.7.The instrument has 8 external event interface with extendable functions,which can work with avariety of functional control valve, performing according to the set timing.8.The memory function can store 20-sample test modes.9.RS232 communication port and LAN port.

Technical Specifications

Oven
Inside capacity22L
Temperature rangeroom temperature up 5 ºC-400ºC
Temperature accuracy±0.1 ºC
Temperature programming9 step
Program Total Time9999.9 min
Max heating rate0.1-60 ºC/min
Max cooling rate≤10mins(250 ºC -50 ºC)
Sample Injector
Temperature rangeroom temperature up7 ºC~ 420 ºC
Temp control typeindependent
Carrier gas flow control typeconstant pressure
Max quantity3PCS
TypePacked column or split
Split ratiodisplay
Pre column pressure range0-400kpa
Pre column pressure accuracy0.1 kpa
Flow setting rangeH2 0-200ml/min N2 0-150ml/min
Detector
FID or TCD, select one only
Temperature Rangeroom temperature up 7ºC~420 ºC
Max installation Qty.2
Ignition modelautomatic
Hydrogen Flame Ionization Detector (FID)Logarithmic amplifierHigh Voltage Switch ControlBaseline signal display
Detection limit≤3x10.12g/s( sample n-hexadecane)
Baseline noise≤5x10-14 A
Baseline draft≤6x10-13 A
Dynamic range107
RSD≤3%
Thermal Conductivity Detector (TCD)
Sencitivity8000mV.ml/mg (sample n-hexadecane)
Baseline noise≤0.05mV
Baseline draft≤0.15mV/ 30min
Dynamic range105
Overall Dimension & Weight
Power220V±22V, 50Hz±0.5Hz, 3000W
Overall Dimension1020x 660x740 (mm)
G.W.82kg
N.W.70kg

Related Recommends


Company Information

High Quality Lab Analysis Instruments Gas Chromatography Instrument

FAQ
> if the machine broke after a period of use, can I return it back and get a refund?
iClear HealthCare has a secure procedure to do the product return and repair, please check our service
policy for more information.
> I have NO experience buying medical stuff in China. Is the quality good?
There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price.
> How long will it take to reach me after the payment?
By Express, it takes 5-7 working days to arrive;
By Air, 3-4 days to the international airport;
By Sea, around 25-55 days to the seaport.
>> Can you help set up a clinic or provide complete equipment for hospital projects?
We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.